Dut-E 2Bio Fuel level sensor

Fuel level sensor DUT-E 2Bio is designed for precision fuel level measurement in all kinds of vehicle tanks, also in tanks of fixed installations.

 

DUT-E 2Bio can be used as a part of a fuel monitoring system or to substitute the standard fuel meter of a vehicle.

Different fuel types (summer diesel, winter diesel and especially biodiesel) have different permittivity values. For accurate fuel volume measurement in case of switching between different types of fuel re-calibration of fuel tank is needed.

 

DUT-E 2Bio fuel level sensor is designed for accurate volume measurement of all types of fuel. 

Re-calibration and re-configurations is not needed.  DUT-E as a part of telematics system is used:

  • to obtain reliable information about current fuel volume in vehicle tank;
  • to define the vehicle fueling volume;
  • to detect fuel theft from the tank;
  • to carry out the remote tank monitoring;
  • to determine fuel consumption.

Features

  • configuratable thermal correction for automatic compensation based on ambient temperature;
  • digital self-diagnostics to control data reliability;
  • conformity to compulsory automobile standards of the European Union, Russia, and Belarus;
  • no recalibration required for up to 30% length reduction of the sensor (DUT-E А5, DUT-E А10, DUT-E I);
  • length increase with additional sections of DUT-E – up to 6000 mm;
  • ergonomic bayonet-type fastening to save mounting time;
  • sealing openings to prevent tampering;
  • all the necessary mounting items and cords in delivery set;
  • filter for secure protection from water and mud;
  • convenient ready output signal showing fuel level in the tank in mm, fuel volume in littres, percentage of full tank capacity;
  • сonfiguration via Bluetooth by connecting S6 BT Service Adapter.

Ordinary capacitive fuel level sensors.

Fuel level sensor sends overestimated fuel volume when switching from regular diesel fuel to biofuel.

DUT-E 2Bio fuel level sensor

Fuel level sensor sends real fuel volume when switching from regular diesel fuel to biofuel.

Correctness of the fuel level sensor reading on biodiesel


Models:


DUT 2Bio CAN: CAN (J1939) interface.

other types of output signal are produced on demand


Technical specifications:


Operation principle ....................................................... Capacitive
Measurement inaccuracy.........................................................1%
Supply voltage, V ............................... 10 .. 50, protection up to 100
Operation temperature, °С ............................................. –40 .. +85
Current consumption (DC 24/12V), mA ............................. ≤ 25/50
Probe length, mm ......................................................... 700, 1000




Recommendations on connecting and set-up of fuel level sensors DUT-E 2Bio  and GPS vehicle trackers can be found on this page.

 

DUT-E fuel level sensor compatibility with terminals

 

 

Price of DUT-E 2Bio fuel level sensor